About
Enhanced Solvency Solution for Oxygen Service Cleaning
Vertrel™ MCA specialty fluid is a proprietary azeotrope of Vertrel™ XF and trans-1,2 dichloroethylene. Its enhanced solvency makes it very effective for precision and specialty cleaning challenges and is designed for use in a vapor degreaser. It is compatible with metals and most plastics and elastomers. Vertrel™ MCA can clean a variety of light and heavy-duty soils, including:
- Cutting oils
- Gear oils
- Heavy greases
- Hydraulic oils
- Stamping oils
- Vacuum oils
- Waxes
- Mineral oils
Features and Benefits
Many features make Vertrel™ MCA specialty fluid the optimal choice for precision cleaning and oxygen service cleaning, including:
- Compatibility with many plastics, elastomers, and metals
- Ability to replace CFC-113, methyl-chloroform (1,1,1-TCA), hydrochlorofluorocarbons (HCFCs), and perfluorocarbons (PFCs) in many applications
- Excellent solvency (KB = 25) with the capability to clean complex geometries
- Non-flammability with no closed-cup or open-cup flash point, and has no vapor flammability limits in air.
Vertrel™ MCA has passed the LOX impact tests (NHB 8060.1 and NF EN 1797), and is:
- Listed by the Compressed Gas Association, Inc (CGA) in the Directory of Cleaning Agents for Oxygen Services and in ASTM G93: "Standard Practice for Cleaning Methods and Cleanliness Levels for Material and Equipment Used in Oxygen-Enriched Environments"
- Approved by major gas producers and aerospace manufacturers for use in oxygen systems
- Recommended for cleaning heavy soils and greases
Table 1. Physical Properties
Property |
Vertrel™ MCA |
CFC-113 |
Molecular Weight |
157 |
187 |
Boiling Point, °C (°F) |
39 (102) |
47.6 (117.6) |
Liquid Density, kg/L |
1.41 |
1.56 |
Vapor Pressure, atm |
0.610 |
TBD |
Surface Tension, N/m |
0.0152 |
TBD |
Freezing Point, °C (°F) |
<-50 (<-58) |
–35 (-31) |
Solubility of Water, wt% |
0.065 |
0.011 |
Heat of Vaporization at Boiling Point, kJ/kg |
181.2 |
TBD |
Heat Capacity, kJ/kg·°C |
1.13 |
TBD |
Viscosity, cP |
0.49 |
0.68 |
Flash Point Closed Cupb Open Cupc |
None None |
None None |
Vapor Flammability in Air, vol% Lower Limit Upper Limit |
None None |
None None |
1. At 25°C (77°F), except where indicated.
2. Pensky-Martens Closed Cup Tester (ASTM D93)
3. Tag Open Cup Tester (ASTM D1310)
Table 2. Density and Vapor Pressure Change with Temperature
Temperature, °C (°F) |
Density, kg/L |
Vapor Pressure, atm |
0 (32) |
1.47 |
0.213 |
10 (50) |
1.44 |
0.339 |
20 (68) |
1.42 |
0.493 |
25 (77) |
1.41 |
0.587 |
30 (86) |
1.39 |
0.726 |
40 (104) |
1.37 |
1.046 |
50 (122) |
1.35 |
1.462 |
60 (140) |
1.33 |
1.985 |
Table 3. Soils Cleaned with Vertrel™ MCA
Cutting Oils |
Stamping Oils |
Gear Oils |
Vacuum Oils |
Heavy Greases |
Waxes |
Hydraulic Oils |
Mineral Oils |
Oxygen Cleaning
Oxygen cleaning requires solvents that have good degreasing properties and a high cleaning effectiveness factor (i.e., Kb value >20). These solvents must also be easy to remove from cleaned parts (i.e., boiling point >25°C [77°F] and <65°C [149°F]), non-corrosive, compatible with commonly used metallic and non-metallic materials, compatible with oxygen (i.e., low particle count), have low NVR, and nonflammable (i.e., no flash point and no flammability limits). Vertrel™ MCA meets these oxygen cleaning requirements as shown in Table 4. Vertrel™ MCA is listed by the Compressed Gas Association in the directory of cleaning agents for oxygen service and also meets liquid oxygen mechanical impact testing in accordance with ASTM method.
Table 4. Oxygen Cleaning Requirements and Vertrel™ MCA
Parameter |
Oxygen Cleaning Requirements |
Vertrel™ MCA |
Kb Value |
>20 |
25 |
Boiling Point |
>25°C (77°F) and <65°C (149°F) |
39°C (102°F) |
Flammability |
None |
None |
Flammability Limits |
None |
None |
Oxygen Compatibility |
Low particle count and non-volatile residue |
See Specifications/Table 8 |
Material Compatibility |
Commonly uses metals and non-metallic materials |
See Metals and Other Compatibility |
Plastic and Elastomer Compatibility
Vertrel™ MCA is compatible with most polymeric materials commonly encountered in degreasing of precision parts. Acrylic, ABS, and polycarbonate parts, particularly if under
Environmental Legislation
Vertrel™ MCA has negligible ozone depletion potential and low global warming potential (Table 7).
Vertrel™ MCA is accepted by the EPA under the SNAP program as a substitute for ozone-depleting substances.
The components of Vertrel™ MCA are listed in the TSCA inventory. One component, HFC-43-10mee, is subject to the Significant New Use Rule (SNUR) and should be used only in the indicated applications. See SDS Regulatory Section.
Vertrel™ MCA is not a hazardous air pollutant (HAP) and, therefore, not subject to NESHAP regulation. Vertrel™ MCA is not included in the SARA Title III Section 313 list of toxic chemicals and is not subject to SARA Title III (EPCRA) reporting requirements.
Enhanced Solvency Solution for Oxygen Service Cleaning
Vertrel™ MCA specialty fluid is a proprietary azeotrope of Vertrel™ XF and trans-1,2 dichloroethylene. Its enhanced solvency makes it very effective for precision and specialty cleaning challenges and is designed for use in a vapor degreaser. It is compatible with metals and most plastics and elastomers. Vertrel™ MCA can clean a variety of light and heavy-duty soils, including:
- Cutting oils
- Gear oils
- Heavy greases
- Hydraulic oils
- Stamping oils
- Vacuum oils
- Waxes
- Mineral oils
Features and Benefits
Many features make Vertrel™ MCA specialty fluid the optimal choice for precision cleaning and oxygen service cleaning, including:
- Compatibility with many plastics, elastomers, and metals
- Ability to replace CFC-113, methyl-chloroform (1,1,1-TCA), hydrochlorofluorocarbons (HCFCs), and perfluorocarbons (PFCs) in many applications
- Excellent solvency (KB = 25) with the capability to clean complex geometries
- Non-flammability with no closed-cup or open-cup flash point, and has no vapor flammability limits in air.
Vertrel™ MCA has passed the LOX impact tests (NHB 8060.1 and NF EN 1797), and is:
- Listed by the Compressed Gas Association, Inc (CGA) in the Directory of Cleaning Agents for Oxygen Services and in ASTM G93: "Standard Practice for Cleaning Methods and Cleanliness Levels for Material and Equipment Used in Oxygen-Enriched Environments"
- Approved by major gas producers and aerospace manufacturers for use in oxygen systems
- Recommended for cleaning heavy soils and greases
Table 1. Physical Properties
Property |
Vertrel™ MCA |
CFC-113 |
Molecular Weight |
157 |
187 |
Boiling Point, °C (°F) |
39 (102) |
47.6 (117.6) |
Liquid Density, kg/L |
1.41 |
1.56 |
Vapor Pressure, atm |
0.610 |
TBD |
Surface Tension, N/m |
0.0152 |
TBD |
Freezing Point, °C (°F) |
<-50 (<-58) |
–35 (-31) |
Solubility of Water, wt% |
0.065 |
0.011 |
Heat of Vaporization at Boiling Point, kJ/kg |
181.2 |
TBD |
Heat Capacity, kJ/kg·°C |
1.13 |
TBD |
Viscosity, cP |
0.49 |
0.68 |
Flash Point Closed Cupb Open Cupc |
None None |
None None |
Vapor Flammability in Air, vol% Lower Limit Upper Limit |
None None |
None None |
1. At 25°C (77°F), except where indicated.
2. Pensky-Martens Closed Cup Tester (ASTM D93)
3. Tag Open Cup Tester (ASTM D1310)
Table 2. Density and Vapor Pressure Change with Temperature
Temperature, °C (°F) |
Density, kg/L |
Vapor Pressure, atm |
0 (32) |
1.47 |
0.213 |
10 (50) |
1.44 |
0.339 |
20 (68) |
1.42 |
0.493 |
25 (77) |
1.41 |
0.587 |
30 (86) |
1.39 |
0.726 |
40 (104) |
1.37 |
1.046 |
50 (122) |
1.35 |
1.462 |
60 (140) |
1.33 |
1.985 |
Table 3. Soils Cleaned with Vertrel™ MCA
Cutting Oils |
Stamping Oils |
Gear Oils |
Vacuum Oils |
Heavy Greases |
Waxes |
Hydraulic Oils |
Mineral Oils |
Oxygen Cleaning
Oxygen cleaning requires solvents that have good degreasing properties and a high cleaning effectiveness factor (i.e., Kb value >20). These solvents must also be easy to remove from cleaned parts (i.e., boiling point >25°C [77°F] and <65°C [149°F]), non-corrosive, compatible with commonly used metallic and non-metallic materials, compatible with oxygen (i.e., low particle count), have low NVR, and nonflammable (i.e., no flash point and no flammability limits). Vertrel™ MCA meets these oxygen cleaning requirements as shown in Table 4. Vertrel™ MCA is listed by the Compressed Gas Association in the directory of cleaning agents for oxygen service and also meets liquid oxygen mechanical impact testing in accordance with ASTM method.
Table 4. Oxygen Cleaning Requirements and Vertrel™ MCA
Parameter |
Oxygen Cleaning Requirements |
Vertrel™ MCA |
Kb Value |
>20 |
25 |
Boiling Point |
>25°C (77°F) and <65°C (149°F) |
39°C (102°F) |
Flammability |
None |
None |
Flammability Limits |
None |
None |
Oxygen Compatibility |
Low particle count and non-volatile residue |
See Specifications/Table 8 |
Material Compatibility |
Commonly uses metals and non-metallic materials |
See Metals and Other Compatibility |
Plastic and Elastomer Compatibility
Vertrel™ MCA is compatible with most polymeric materials commonly encountered in degreasing of precision parts. Acrylic, ABS, and polycarbonate parts, particularly if under
Environmental Legislation
Vertrel™ MCA has negligible ozone depletion potential and low global warming potential (Table 7).
Vertrel™ MCA is accepted by the EPA under the SNAP program as a substitute for ozone-depleting substances.
The components of Vertrel™ MCA are listed in the TSCA inventory. One component, HFC-43-10mee, is subject to the Significant New Use Rule (SNUR) and should be used only in the indicated applications. See SDS Regulatory Section.
Vertrel™ MCA is not a hazardous air pollutant (HAP) and, therefore, not subject to NESHAP regulation. Vertrel™ MCA is not included in the SARA Title III Section 313 list of toxic chemicals and is not subject to SARA Title III (EPCRA) reporting requirements.
VERTREL MCA
Translation missing: en.products.product.sku:9753-10
- Regular price
- $386.84
- Sale price
- $386.84
- Regular price
-
Shipping Policy
Shipping Policy
Return Policy
Return Policy
Schedule B Code: 3824.90.5500
Brand & Series: Vertrel MCA
MPN: 0000
CAS #: 138495-42-8 / 156-60-5
MIL-SPEC #: None