About
TMC-367E is a precision cleaning solvent mixture of 1,2-trans-dichloroethylene and proprietary fluorinated compounds. It was designed with no HFCs, for cleaning applications as a direct substitute for solvents like nPB, Chemours Vertrel®, 3M Novec®, HCFC-225, and others.
- LOW VOC CONTENT
- LOW VISCOSITY
- ZERO SURFACE RESIDUE
- NON-FLAMMABLE
- NO FLASH POINT
APPLICATIONS
This solvent blend is perfectly suited for vapor degreasing in modern equipment, refrigerant flush applications, and many others. Its solvency for hydrocarbon soils and fluxes is excellent. It can reliably replace cleaning solvents such as n-propyl bromide (nPB), trichloroethylene (TCE), Vertrel™, Novec™, HCFC-225, and others in many applications. It can also be used as a carrier fluid for the deposition of materials such as silicone and other oils.
PHYSICAL PROPERTIES
Appearance |
Clear & Bright |
Flash Point |
None |
Boiling Point |
39°C |
KB Value |
63 |
Specific Gravity |
1.362 g/mL@ 25°C |
Viscosity |
0.41CP @ 20°C* |
Heat Capacity |
0.270cal/g @ 20°C* |
Vapor Pressure |
368 mmHg @ 20°C* |
Relative Density |
1.362 @ 25° C |
Vapor Flammability in Air |
Lower Limit – 6.7%* Upper Limit – 19%* |
VOC Content |
587 g/L 4.89 lbs/gal |
ODP |
0 |
GWP |
580 |
MATERIAL COMPATABILITY
- Polyethylene
- Polypropylene
- Polyvinylchloride (PVC, CPVC)
- Acetal
- Polyester (PET, BET)
- Epoxy
- Polyimide (PI, PEI, PAI)
- PTFE, Teflon
- Polyetherketone (PEK)
- Polysulfone (PSO)
- Polyaryletherketone (PEEK)
- Phenolic
- Polyarylsulfone (PAS)
- Ionomer
- Polyphenylene Sulfide (PPS)
- EPDM
Incompatible Materials
Polystyrene Epichlorohydrin
Polyphenylene Oxide (PPO) Silicone
Polycarbonate Natural Rubber
ABS Acrylic
ENVIRONMENTAL PROPERTIES
TMC-367E ingredients are listed as acceptable by the U.S. EPA under the SNAP program as a substitute for ozone-depleting substances and are not subject to SARA Title III (EPCRA) reporting regulation. It is not considered a Hazardous Air Pollutant (HAP) and therefore is not regulated under NESHAP.
Spent TMC-367E is not considered hazardous waste in the US as long as a hazardous material is not deposited into the solvent during the cleaning process.
FLAMMABILITY
TMC-367E exhibits no flash point on either Pensky-Martens Closed Cup (ASTM D93) or Tag Closed Cup (ASTM D56) methods and is not classified as flammable by OSHA or DOT. However, as is true with almost all halogenated solvents, it does have flammable limits in air in the presence of a high ignition energy source (e.g., a welding torch). TMC-367E is not classified as flammable or hazardous for transport by DOT.
STORAGE & HANDLING
TMC-367E is thermally stable and will not oxidize or degrade during storage under normal conditions. It is recommended to store the product inside a clean, dry area and out of direct sunlight or other heat sources. Do not freeze or store below 32°F (0°C) nor above 90°F (32°C) to prevent leakage or potential rupture of container due to contraction/expansion and pressure changes. Drum pumps are recommended to dispense the solvent from its container. Refer to the Safety Data Sheet for more information or contact TMC Industries, Inc. for further assistance.
DOCUMENTS
TMC-367E is a precision cleaning solvent mixture of 1,2-trans-dichloroethylene and proprietary fluorinated compounds. It was designed with no HFCs, for cleaning applications as a direct substitute for solvents like nPB, Chemours Vertrel®, 3M Novec®, HCFC-225, and others.
- LOW VOC CONTENT
- LOW VISCOSITY
- ZERO SURFACE RESIDUE
- NON-FLAMMABLE
- NO FLASH POINT
APPLICATIONS
This solvent blend is perfectly suited for vapor degreasing in modern equipment, refrigerant flush applications, and many others. Its solvency for hydrocarbon soils and fluxes is excellent. It can reliably replace cleaning solvents such as n-propyl bromide (nPB), trichloroethylene (TCE), Vertrel™, Novec™, HCFC-225, and others in many applications. It can also be used as a carrier fluid for the deposition of materials such as silicone and other oils.
PHYSICAL PROPERTIES
Appearance |
Clear & Bright |
Flash Point |
None |
Boiling Point |
39°C |
KB Value |
63 |
Specific Gravity |
1.362 g/mL@ 25°C |
Viscosity |
0.41CP @ 20°C* |
Heat Capacity |
0.270cal/g @ 20°C* |
Vapor Pressure |
368 mmHg @ 20°C* |
Relative Density |
1.362 @ 25° C |
Vapor Flammability in Air |
Lower Limit – 6.7%* Upper Limit – 19%* |
VOC Content |
587 g/L 4.89 lbs/gal |
ODP |
0 |
GWP |
580 |
MATERIAL COMPATABILITY
- Polyethylene
- Polypropylene
- Polyvinylchloride (PVC, CPVC)
- Acetal
- Polyester (PET, BET)
- Epoxy
- Polyimide (PI, PEI, PAI)
- PTFE, Teflon
- Polyetherketone (PEK)
- Polysulfone (PSO)
- Polyaryletherketone (PEEK)
- Phenolic
- Polyarylsulfone (PAS)
- Ionomer
- Polyphenylene Sulfide (PPS)
- EPDM
Incompatible Materials
Polystyrene Epichlorohydrin
Polyphenylene Oxide (PPO) Silicone
Polycarbonate Natural Rubber
ABS Acrylic
ENVIRONMENTAL PROPERTIES
TMC-367E ingredients are listed as acceptable by the U.S. EPA under the SNAP program as a substitute for ozone-depleting substances and are not subject to SARA Title III (EPCRA) reporting regulation. It is not considered a Hazardous Air Pollutant (HAP) and therefore is not regulated under NESHAP.
Spent TMC-367E is not considered hazardous waste in the US as long as a hazardous material is not deposited into the solvent during the cleaning process.
FLAMMABILITY
TMC-367E exhibits no flash point on either Pensky-Martens Closed Cup (ASTM D93) or Tag Closed Cup (ASTM D56) methods and is not classified as flammable by OSHA or DOT. However, as is true with almost all halogenated solvents, it does have flammable limits in air in the presence of a high ignition energy source (e.g., a welding torch). TMC-367E is not classified as flammable or hazardous for transport by DOT.
STORAGE & HANDLING
TMC-367E is thermally stable and will not oxidize or degrade during storage under normal conditions. It is recommended to store the product inside a clean, dry area and out of direct sunlight or other heat sources. Do not freeze or store below 32°F (0°C) nor above 90°F (32°C) to prevent leakage or potential rupture of container due to contraction/expansion and pressure changes. Drum pumps are recommended to dispense the solvent from its container. Refer to the Safety Data Sheet for more information or contact TMC Industries, Inc. for further assistance.
DOCUMENTS
TMC-367E ENGINEERED FLUID
Translation missing: en.products.product.sku:2504E-10
- Regular price
- $196.70
- Sale price
- $196.70
- Regular price
-
Shipping Policy
Shipping Policy
Return Policy
Return Policy
Schedule B Code: 3827.90.0000
Brand & Series: TMC-367E
MPN: 2504E
CAS #: 156-60-5
MIL-SPEC #: None